Smoke Detector > 1400 Direct Wire Ionization

Specifications

Diameter: 5.5 inches (140 mm)
Height: 3.12 inches (80 mm)
Weight: 0.7 lb. (310 g)
Operating Temperature: 0°C to +49°C (32°F to 120°F)
Latching Alarm: Reset by momentary power interruption.

Operating Humidity: 10% to 93% Relative Humidity, Noncondensing
Electrical Ratings:
System Voltage: 12/24 VDC
Maximum Ripple Voltage: 4 Volts peak to peak

Start-up Capacitance: 0.02 μA Maximum
Standby Ratings: 8.5 VDC Minimum ; 35 VDC Maximum ; 100 μA Maximum
Alarm Ratings: 4.2 VDC Minimum at 10 mA; 6.6 VDC Minimum at 100 mA

Alarm current must be limited to 100 mA maximum by the control panel. If used, the RA400Z Remote Annunciator operates within the specified detector alarm currents.

Reset Voltage: 2.5 VDC Minimum
Reset Time: 0.3 S Maximum
Start-up Time: 35 S Maximum


Before Installing

Please thoroughly read the System Sensor manual A05- 1003, Applications Guide for System Smoke Detectors. This manual provides detailed information on detector spacing, placement, zoning, wiring, and special applications. Copies of this manual are available at no charge from System Sensor.



General Description

System Sensor 1400 dual-chamber ionization smoke detectors utilize state-of-the-art, unipolar sensing chambers. These detectors are designed to provide open area protection, and to be used with compatible UL-listed, 2-wire control panels only. The detector’s operation and sensitivity can be tested in place.

Each detector includes an LED that provides a local visual indication of the detector’s status. The LED blinks every ten seconds as an indication that power is applied to the detector and lights continuously in alarm. These detectors also have the latching alarm feature. The alarm can be reset only by a momentary power interruption. The detector also has provision for the connection of an optional Model RA400Z Remote Annunciator. The RA400Z provides a visual indication of an alarm and mounts to a single gang box.


Spacing

NFPA 72 defines the spacing requirements for smoke detectors. Typically, this is 30 feet when the detectors are installed on a smooth ceiling. However, ALL installations must comply with NFPA 72 and/or special requirements of the authority having jurisdiction.

Smoke detectors and alarm system control panels have specifications for allowable loop resistance. Consult the control panel manufacturer’s specifications for the total loop resistance allowed for the control panel being used before wiring the detector loops.


For more information.
Please contact
Mr. Rudolf Lumempouw
M. +62 815-1462-0538
Jakarta Indonesia
email. rudolflumempouw@yahoo.co.id

Nov 16, 2008

Surge Arrestor > TITAN DR Surge Protective Devices (SPD)

Introduction

These Surge Protective Devices (SPD) provide surge protection for electrical and automation cabinets. They can be mounted on standard 35 mm rail near the incoming power source to isolate the cabinet from the outside environment. This product is ideal for manufacturers and electrical installers requiring designed-in power protection.
NOTE: Must be installed with the proper Merlin Gerin Supplementary Protector (MGSP).



DIN Rail mounted surge protection

EFI’s Titan DR SPD systems provide highquality surge protection for electrical and automation cabinets. The Titan DR can be mounted on standard 35 mm rail prior to the incoming power source to isolate the cabinet from the outside environment. This product is ideal for manufacturers and electrical installers requiring designedin power protection.



DANGER

Hazard Of Electric Shock, Explosion, Or Arc Flash

· This equipment must be installed and serviced only by qualified electrical personnel in accordance with National and Local Electrical Codes.

· Turn off all power supplying this equipment before working on or inside equipment.

· Always use a properly rated voltage sensing device to confirm power is off.

· Replace all devices, doors, and covers before turning on power to this equipment.

· Do not apply petroleum-based products to non-metallic parts.

Failure to follow these instructions will result in death or serious injury.



CAUTION

HAZARD OF Equipment Damage

· Megger® or hi-potential tests will damage this surge protective device. Turn off all power supplying the equipment and isolate the surge protective device before testing.

· Must be installed with the proper Merlin Gerin Supplementary Protector (MGSP).

· Not for use on ungrounded systems.

Failure to follow these instructions can result in equipment damage.



APPLICATIONS

EFI’s new Titan DR Surge Protection Devices (SPD) provide
protection for single and multi-pole applications. The DR is ideal for
manufacturers and integrators of industrial, medical and commercial
instrumentation equipment.



SUPERIOR PE RFORMANCE
The Titan DR provides protection up to 80kA from voltage surges generated by lightning, power supplier network switching, motors, frequency converters, etc.
The Titan DR provides safe and reliable operation by incorporating thermal fusing. Each MOV is individually fused for maximum safety.
The Titan DR has been tested in accordance with UL 1449-2, CE and IEC 61643-1.



EASY INSTALLATION
The Titan DR mounts quickly and easily to mounting rails (35mm).
25mm2 connectors provide easy parallel connection providing greater
installation flexibility, even where space is limited.
The plug-in module of the single pole device allows replacement of a
damaged SPD while still connected to the mounting rail and power.



PLUG – IN


Single pole devices feature plug-in module design. User-replaceable module allows easy replacement of damaged SPD modules without any electrical wiring. Plug-in module also provides high flexibility when testing the isolation resistance of electrical cabinets.

Contact
Mr. Leong
Leatrimatik Sdn. Bhd
No. 4,
Jalan Tpk 2/4,
Taman Perindustrian Kinrara,
Batu 7 1/2, Off Jalan Puchong, 47100 Puchong, Selangor D.E. Malaysia
aldemar.guerra@us.schneider-electric.com

or

Aldemar Guerra
Technical Sales Manager
Efi Electronics Europe S.L.
C/ Albert Einstein 43
08940, Cornella de Llobregat (Spain)
Tel. : +34 93 4800630
Fax : +34 93 3777859
Mobile : +34 618815776
http://www.efinet.com
E-mail: aguerra@efinet.com

Nov 15, 2008

Surge Arrestor > N-Female to N-Female Bulkhead 0-3 GHz 230V Lightning Protector

Features for this Lightning Protectors product

  • Reliable Performance from DC ~ 3 GHz
  • Bi-Directional Protection
  • Protector will pass DC
  • Easily Replaced Gas Tube Element, Mounting Bracket Included
  • Multi-Strike Capability
The AL-NFNFB-2 is a gas discharge tube suppressor featuring wide-band operation up to 3 GHz. This unit features a N-Female to N-Female Bulkhead connector with a rubber "O"-ring seal for mounting through an enclosure wall or with the included aluminum mounting bracket.
Due to its low cost and superior RF performance, this unit is ideal for IEEE 802.11b and 802.11g Wireless LAN applications, as well as ISM, MMDS, Cellular, and PCS applications. Since this protector will pass DC, it is suitable for applications where DC is carried through the coax cable, such as remote amplifiers and LNAs.

Both connector ports of this unit are equally protected. This provides protection no matter which way it is installed. Either port can face the antenna and either port can face the equipment.
The unit's replaceable gas tube element, multi-strike capability, and fast response time make it suitable for a wide range of applications. A ground lug and terminal are supplied directly on the lightning protector housing, which provides superior grounding.


Details for this Lightning Protectors product


Applications for this Lightning Protectors product

IEEE 802.11b and 802.11g Wireless LAN applications
ISM
MMDS
Cellular application
PCS applications

In Indonesia
Contact
Mr.
Felix Suhendar
M. +62 8123006300
PT. Angin Jaya Solusi
Jl. Mayjend Sungkono 83
Surabaya - 60242
T. +62 31 5680390
F. +62 31 5669961
felix@angin.com
www.angin.com

Surge Arrestor > AL-CAT5VW

Outdoor 10/100 Base-T CAT5 Lightning Surge Protector - RJ45 Jacks
Features for this Lightning Protectors product

10/100 Base-T CAT5 protection
Power-Over-Ethernet Compatible
Cisco® Reverse Polarity PoE compatible
Impact and weather resistant, locking hinged cover
(2) RJ45 Jacks


Power-Over-Ethernet (PoE) Compatible

The AL-CAT5VW is a Compact Weather Resistant Lightning Protector which provides lightning and surge protection for CAT5 data applications. The unit is fully compatible with industry-standard Power-over-Ethernet (PoE) devices and 10/100 Base-T Ethernet networks, providing protection to both Ethernet data pairs as well as the PoE DC power feed.

High speed semiconductors clamp any voltage, positive or negative on the wires. The limits are +/- 15 volts on pins, 1, 2, 3 and 6 and +/- 58 volts on pins 4, 5, 7 and 8. The unit is compatible with both normal and inverted polarity voltage PoE equipment. For maximum protection two AL-CAT5VW units should be used, one at each end of the CAT5 cable. Most PoE capable equipment is not protected from surges on it's CAT5 cable.

This Lightning Protector is compatible with both 10 Base-T and 100-Base devices as well as Power-over-Ethernet (PoE) devices, including Wireless Access Points, Access Servers and Outdoor Routers that support Power-over-Ethernet (PoE).

A ground lug and terminal is provided in the lightning protector housing providing superior grounding.

The compact weather resistant housing features a lockable hinged cover and break-away holes are provided on the rear of the enclosure for mounting. The cable grommets may be adjusted to cable size and are removable.

Cisco CompatibleThis lightning surge protector is compatible with Cisco Aironet® 1100 and 1200 series access points, DC Injectors and other equipment supporting reverse polarity PoE pinouts.

Applications for this Lightning Protectors product
• 10/100 Base-T CAT5 protection
• Wireless Access Points & Servers
• Wireless Outdoor Routers

In Indonesia.
Contact.
Mr. Felix Suhendar
M. +62 8123006300
PT. Angin Jaya Solusi
Jl. Mayjend Sungkono 83
Surabaya - 60242
T. +62 31 5680390
F. +62 31 5669961
felix@angin.com
www.angin.com

Surge Arrestor > Outdoor Installation Warning

Important Safety Precautions

Lives may be at risk.

Carefully observe these instructions and any special instructions that are included with the equipment you are installing

Importan : Look over the site before beginning any installation, and acticipate possible hazards, especially these :


Contacting power lines can be lethat. Make sure no power lines are anywhere where possible contact can be made.
Antennas, masts, towers, guy wires or cables may lean or fall and contact these lines. People may be injured or killed if they are touching or holding any part of equipment when it contacts electric lines. Make sure there is NO possibility that equipment or personnel can come in contact directly or indirectly with power lines.

Assume all overhead lines are power lines.

The horizontal distance from a tower, mast or antenna to the nearest power line should be at least twice the total length of the mast/ antenna combination. This will ensure that the mast will not contact power if it falls either during installation or later.

To avoid falling, use safe procedure when working at heights above ground.

Select equipment locations that will allow safe, simple equipment installation
Don’t work alone. A friend or co-worker can save your life if an accident happens.
Use approved non-conducting ladders and other safety equipment. Make sure all equipment is in good repair.
If a tower or mast begins falling, don’t attempt to catch it. Stand back and let it fall.
If anything such as a wire or mast does come in contact with a power line., don’t’thouch it or attempt to move it. Instead, save your life by calling the power company.

Don’t attempt to erect antennas or towers on windy days.

Nov 9, 2008

KVM Switch > Adder AdderLink ipeps Dual Access KVM over IP Solution

The AdderLink ipeps AL-IPEPS-DA KVM over IP dual access unit which is part of Adder’s IP Engine per Server or "ipeps" concept that delivers a complete, secure, non-blocking approach to computer management.The ipeps is a powerful and flexible KVM-via-IP product contained with in a palm sized unit which enables computer access from anywhere in the world, securely and remotely via the Internet or corporate network. The AdderLink ipeps uses Real VNC client software that is specifically designed for secure, high performance KVM via IP applications.

This IP unit uses Adventiq Inside on-chip KVM over IP technology, enabling it to be an extremely high performance solution despite its compact size.For Enterprise KVM solutions the AdderLink ipeps provides a non-blocking global solution by providing each computer with a dedicated KVM-via-IP engine.

This can be enhanced by using the ADDER.NET Enterprise management software that provides a centralized and secure user access management interface. Where a KVM switch exists without KVM-via-IP functionality, the AdderLink ipeps is ideal for adding global management capabilities.Increasing numbers of computers are being used in remote, stand alone applications such as ATMs and digital signage play out devices.

The incredibly small size of the AdderLink ipeps makes it perfect for remote management and control of dispersed computers, meaning that many tasks that would have required an expensive site visit can now be done from anywhere.


AdderLink ipeps Features:


Interface powered, optional external PSU available
Independent operation gives full control even during boot up, BIOS level or computer crash states
USB or PS/2 keyboard and mouse connections
Virtual media support (via USB)
High performance video
Enterprise grade security (using AES 128 bit encryption and RSA 2048 bit public key authentication) further enhanced by the use of Real VNC that allows for the creation of ciphered user communications.
16 user profiles and access data logging
Up to 16 units can be rack mounted in 2U of rack space
Can be used as a KVM front end
Compatible with most third party KVM switches
Supports exclusive access mode or up to four simultaneous connections
ipeps DA model has feed through port that provides local KVM console access
Auto sensing 10/100 Mb Ethernet port

Nov 7, 2008

KVM Switch > Minicom Smart 216 IP KVM Switch

The Minicom Smart 216 IP multi-user IP KVM Switch which enables one local and two remote users, access and control of up to 16 servers. In addition, two remote users can operate serial sessions for controlling serial devices such as routers, managed network switches or PDU's. These rack-mountable, 1U sized switches feature KVM over CAT5 technology that directly connects the switch to each computer in the server room, eliminating cable clutter and providing up to 30m/100ft of distance between server and switch. The Smart 216 IP has built-in web servers enabling two remote users seamless access to target servers via a single IP address. This IP KVM Switch offers seamless integration into Minicom’s centralized management system – KVM.net® II.

Minicom Smart 216 IP Features:
3 simultaneous KVM users (2 remote and 1 local)
2 additional serial session users
BIOS level access
USB keyboard and mouse console
Compatible with KVM.net® II centralized management system
Minicom KVM over CAT5 technology
Multi-platform – PS/2 and USB support
Extends distance between servers and switch up to 30 meters/100 feet
Space saving – sleek, 1U rack mountable
Seamless power control

KVM Switch > Avocent AutoView 8 Port, Dual User, CAT5 KVM Switch

The Avocent AV1515-001 8-port AutoView multi-user KVM switch provides user support for USB and/or PS/2 keyboards and mice. This 8 port KVM switch also provides support for USB, PS/2, Sun, and serial target devices. Built for SMB server room environments, the AutoView 1515 switch all-in-one solution provide the convenience of a high-quality, On-Screen Display (OSD). The AutoView AV1515 switch includes two unique cabling options. Integrated access cables provide PS/2 and USB support and are available in lengths of 7, 10 and 15 feet. The server interface module, with Sun and serial support, covers a range of 100 feet between the target device and the switch. Both cabling options automatically assign and retain unique server names for each attached server, which simplifies installation and eases re-configuration


Avocent AV1515-001 Features:

Dual-user, 8-port KVM switch
Includes two unique cabling options
Powerful user access control: Allows an administrator complete control over the KVM switch setting and allows granting KVM access to only certain users.
Sun keyboard localization: Supports international markets
Sun keyboard translation: Allows users to use PS/2 keyboards with Sun targets.
OSCAR graphical user interface- Multilingual OSD: makes it easy for users to switch, monitor, and locate target devices.
Integrates with Avocent AutoView 3100 and 3200 KVM switches
Operating System (OS) independent: Ensures connection to the attached servers regardless of the health or type of OS

IT Conversations

Moneycontrol Latest News

Latest new pages on Computer Hope

Latest from Infoworld

Door Lock

Door Lock Import Top Door Lock from China Contact Quality Manufacturers Now